With help of this instrument user can find out density of plastic row material mainly of powder and granual form. This is easiest and fasted method to find out density of material. Machine designed and construction as per ASTM, ISO, IS or other equivalent standards. Specifications: |
![]() |
||||||||||||||
| Loading funnel with lock : | 115ml Base plate with supporting measuring cup:100ml±0.5ml with collecting pan. | ||||||||||||||
| Weights approx : | 3kg | ||||||||||||||
|
|
|||||||||||||||
|
To test the carbon black rate of polyolefin DSH sets together for you all necessary elements of this laboratory process in a completely assembled compact module. Tube furnace all glass-wares, rubber pipes are clearly visible and fastener on a solid wooden panel. A further benefit is the safe procedure, nothing can drop off, and the tubes are securely fastened and never come in touch with the hot agents. Table top model and working height platform required at user’s end. Specifications: |
![]() |
||||||||||||||
| Temperature range : | Maximum up to 1000°c | ||||||||||||||
| Working temperature range : | Up to 800°c | ||||||||||||||
| Temperature accuracy and least count : | Temperature accuracy | ||||||||||||||
| better than ±5°c | |||||||||||||||
| and least count ±1°c. | |||||||||||||||
| Power supply : | 240vAC, single phase 50Hz | ||||||||||||||
| Heater capacity : | Maximum 2kw tubular type. | ||||||||||||||
|
|
|||||||||||||||
|
Laboratory type microscope model is used to find out uniform carbon dispersion in polyolefin samples. DSH provided different type of models as per product sensitivity and clearance. Projection type model, zoom stereo type model, light adjustment and mechanical platform moving and measuring facility also available to operate easy and user friendly. In case of CCD camera unit attached test analyze software is also provided. Thermostatically operated hot plate is also provided with the carbon black dispersion unit. Hot plate is also optional Digital temperature controller is also provided on request. |
![]()
|
||||||||||||||
|
Models: |
|||||||||||||||
| Projection Type | |||||||||||||||
| Zoom Stereo | |||||||||||||||
| CCD camera unit is also with software and USB attachment. | |||||||||||||||
|
|
|||||||||||||||
|
The friction tester is designed to determine the friction of plastic films, sheets, laminates, pipes and paper. With help of this equipment user can find out Static COF and in case of computer interface model kinetic COF also grab. Machine designed as per ASTM, ISO, BS or other equivalent standards. Friction tester is also as known as Slip tester. Specifications: |
![]() |
||||||||||||||
| Load capacity : | Maximum capacity 3kg or higher on request | ||||||||||||||
| Mechanical driven : | Single screw driven with friction less guide bushes. | ||||||||||||||
| Speed selection : | Variable speed drive with safety traveling limit switches. | ||||||||||||||
|
|
|||||||||||||||
|
This test method covers the determination of the density of solid plastics. This test method is based on observing the level to which a test specimen sinks in a liquid column exhibiting a density gradient, in comparison with standards of known density. The test conduct temperature is 23°c, so chilling unit is required for the test. Specifications: |
![]() |
||||||||||||||
| No of column : | Two columns or single column | ||||||||||||||
| Chiller Chilling unit is supply with the machine (optional at extra cost) | |||||||||||||||
| Glassware’s & Accessories Test conduct glassware’s and one time test chemical also provided with the machine. | |||||||||||||||
| Density range : | 0.8g/cm³ to 2.0g/cm³. | ||||||||||||||
|
|
|||||||||||||||
|
This test is suitable for polyethylene samples of pipes and sheets. With help of this test method user can find out effect in presence of soap liquid. Another test method for ESCR is by oven method for this procedure oven is required. Test temperature bath and complete test conduct kit is supply with the machine. Environmental stress-cracking is a property that is highly dependent upon the nature and level of the stresses applied and on the thermal history of the specimen. Specifications: |
![]()
|
||||||||||||||
| Water Bath : | Bath construction is inside stainless steel out side mild steel. | ||||||||||||||
| Insulation : | Glass wool insulation is used for heat losses. Bath open able door also insulated. | ||||||||||||||
| Temperature range : | From room temperature to 100°c. | ||||||||||||||
| Temperature accuracy : | Better than ± 1°c. | ||||||||||||||
| Accessories : | Blanking Die, Nicking jig, Specimen Holder, Glass test tube with rubber cock, Bending clamp , transfer tool. | ||||||||||||||
|
|
|||||||||||||||
|
These test methods cover the determination of the energy that causes plastic film to fail under specified conditions of impact of a free-falling dart. This energy is expressed in terms of the weight of the missile falling from a specified height which would result in 50% failure of specimens tested. In the machine there is a clamping device, darts, positioning device for dart falling facility. A position measuring system that measures absolutely is fitted to the drop shaft. Specifications: |
![]() |
||||||||||||||
|
|
Specimen clamp : | A two piece annular specimen clamp as per standard. | |||||||||||||
|
|
Electro magnet : | Capable of supporting a 2kg weight for use in supporting and releasing the dart assembly. | |||||||||||||
|
|
Darts & Weights : | According to the standard method A and method B type darts are provided. Darts are made from different material of SS, Aluminum and high lam. All range weights from 1gms to 200gms. | |||||||||||||
|
|
Height adjustment: | Height adjustment rod is also providing with machine. | |||||||||||||
|
|
|||||||||||||||
|
Vicat softening Point This test method covers determination of the temperature at which a specified needle penetration occurs when specimens are subjected to controlled test conditions. This test method is not recommended for ethyl cellulose, non- rigid poly, poly or other materials having a wide vicat softening range. Heat Deflection tester This test method covers the determination of the temperature at which an arbitrary deformation occurs when specimens are subjected to an arbitrary set of testing conditions. This test method applies to molded and sheet materials available in thickness of 3mm or greater and which are rigid at normal temperature. Specifications for Analogue model : |
![]() |
||||||||||||||
| Deflection Measurement Deflection or Penetration measurement system by analogue type dial gauge. | |||||||||||||||
|
|
Dial gauge range & least count : Analogue type dial gauge range is 0-10mm with accuracy of 0.1mm. Vibration free baker or Adis make dial gauge. | ||||||||||||||
| Temperature controller : Digital type temperature controller. | |||||||||||||||
| Temperature range : +20°c to +300°c with 0.1°c least count. | |||||||||||||||
|
|
Rate of rise : Temperature rate of rise is as per standard , 50°c/hr or 120°c/hr. | ||||||||||||||
| Immersion bath : Heat oil bath is used. Construction of bath is inside stainless steel and out side mild steel with powder coats. | |||||||||||||||
|
|
Indenter : Separate indenter for HDT and VSP test according to the standard. | ||||||||||||||
|
|
Cooling : Cooling facility is provided to start the test after completion of the same test. | ||||||||||||||
| Specifications Digital model with computer interfacing facility : | |||||||||||||||
| No of stations: | Maximum 3 measuring stations and heat exchanger for determination of VICAT and Heat Deflection test. | ||||||||||||||
|
|
Test control : | Complete test control via computer interfacing facility. | |||||||||||||
|
|
Digital Deflection system : | Deflection in case of HDT and Penetration in case of VSP test is measuring facility via digital deflection indicator with help of LVDT. | |||||||||||||
| Temperature controller : | Digital temperature controller and temperature rate of rise or ramp rate is also free programmable and auto select as per test requirement when selection of the type of test. | ||||||||||||||
| High power cooling : | Cooling facility is incorporate with the instrument. With help of the high power cooling facility user can start another test in very short period. | ||||||||||||||
| Oil bath : | Inside stainless steel and out side Mild steel powder coated immersion type oil bath with immerse type heater fitted is provided. | ||||||||||||||
| Software : | User friendly easy operation based Lab-view type software is supply with the equipment. Software having a facility of Live graph plotting with auto scaling. Graph plotting facility is Temperature or Time Vs Deflection/Penetration. | ||||||||||||||
|
|
|||||||||||||||
|
This instrument is cover laboratory measurement of the strength of heat seals formed between thermoplastic surfaces of flexible webs. And these sealed samples are tested on to the tensile testing machine. |
![]() |
||||||||||||||
|
Specifications : |
|||||||||||||||
| Machine construction : |
Pneumatically operated Jaws. |
||||||||||||||
|
|
Temperature zone : | Upper Jaw and lower jaw both have separate heater with separate temperature control device fitted. | |||||||||||||
|
|
Temperature controller: | PID based temperature controller with auto tune facility. Maximum temperature range is up to 200°c with accuracy ±0.5°c. | |||||||||||||
| Heating jaws : | One jaw is fixed and another jaw is operated with help of pneumatic system. | ||||||||||||||
| Daylight opening : | Maximum daylight opening between two jaws is 100mm. Maximum sealing length 400mm and sealing width is 20mm maximum. | ||||||||||||||
|
|
|||||||||||||||
|
Ovens are very widely used in different industries at different laboratory. Different test conditioning ovens are made by us. Different application different sizes are available. |
![]() |
||||||||||||||
|
Specifications : |
|||||||||||||||
| Construction : | Oven made from inside stainless steel and out side Mild steel with fully powder coated. | ||||||||||||||
|
|
Insulation : | Heavy insulation between outer surface and inner surface.Insulation is mainly glass wool or cera wool as per maximum working temperature of the oven. | |||||||||||||
|
|
Temperature : |
Digital microprocessor based auto tune facility temperature controller is used to maintained temperature with in range. |
|||||||||||||
| Temperature range : | Temperature range as per customer requirements. General temperaturerange is up to 200°c. Temperature least count is 0.1°c and accuracy better than ±1°c of set temperature. | ||||||||||||||
| Sizes : | 12”x12”’x12, 14”x14”x14”, 18”x18”x18”, 24”x24”x24”, 36”x36”x36” or customized. | ||||||||||||||
| Circulating : | Air circulating facility is provided to maintained uniform temperature into the chamber. Also temperatures cross check point provided into the oven. | ||||||||||||||
|
|
|||||||||||||||
|
A special combination system, combined with the temperature controller, ensure high accuracy a homogenous temperature distribution in the entire test bath. All samples are tested under same conditions and with extreme low energy consumption. |
![]() |
||||||||||||||
|
Specifications : |
|||||||||||||||
| Construction : | Sturdy design inside stainless steel out side mild steel with powder coated. | ||||||||||||||
|
|
Insulation : | Five side glass wool insulation. | |||||||||||||
| Application : | Burst pressure test on tubes and pipes, ageing test for plastics, conditioning test for different materials. | ||||||||||||||
| Temperature range : | As per customer application hot water bath and cold water bath is available. | ||||||||||||||
|
|
Sizes : | 48”x30”x18”, 48”x30”x28”, 40”x20”x40”, 60”x30”x46”, 100"x40"x48" inch. Special design is available on request. | |||||||||||||
|
|
|||||||||||||||
|
Humidity chamber is used for conditioning purpose in laboratory. In physical property test all the samples has to be conditioning at relevant temperature at relevant humidity for certain period. |
![]() |
||||||||||||||
|
Specifications : |
|||||||||||||||
| Principal : | Humidity works on dry bulb and wet bulb difference principal. | ||||||||||||||
|
|
Construction : | Linner chamber and tray are made from stainless steel. | |||||||||||||
| Doors : | Outer door made from mild steel and inner door is full length of glass. | ||||||||||||||
| Range : | For humidity 40% to 95% and temperature from ambient to 50°c maximum. Other range is available in special case on demand. | ||||||||||||||
| Protection : | Temperature and humidity over range protection water level protection also fitted. | ||||||||||||||
|
|
|||||||||||||||
|
Digital – Airless system with computer interfacing The hydro-static pressure testing machine is used to find out the internal hydro-static pressure characteristic of FRP,R-PVC, HDPE, C-PVC, MDPE & LLDPE pipes according to different standards. Specifications : |
![]() |
||||||||||||||
|
|
Number of stations : | In modules of 3 stations (or Customized) | |||||||||||||
| Pressure range : | Up to 50/100bars | ||||||||||||||
| Pressure control : | Self-optimizing | ||||||||||||||
| Pressure transducers: | Selectable:10, 16, 25, 40, 60 and 100bars | ||||||||||||||
| Recommended working : | Between 50% and 95% of full scale of pressure transducer. | ||||||||||||||
| Pressure supply : | From central pressurized water supply booster pressure. | ||||||||||||||
| Software : | User friendly data-logging software up to 10000hrs test duration. | ||||||||||||||
| Analogue Model : |
![]() |
||||||||||||||
| Pressure rang : | Up to 50kg/cm² or according to customers’ requirements. | ||||||||||||||
| Pressure controlling : | Pressure is controlled by electro-mechanical contact type gauge. | ||||||||||||||
| Indications : | Pipe failure indicating device is also provided with buzzer out put. | ||||||||||||||
| No. of stations : | Machine provides with single, two, three up to six stations. | ||||||||||||||
| Pressure generation : | From central pressurized water supply booster pressure. | ||||||||||||||
| Calibration : | Master pressure gauge is also provided (optional). | ||||||||||||||
|
|
|||||||||||||||
|
These test methods cover the determination of the resistance of plastics to breakage by flexural shock as indicated by the energy extracted from standardized pendulum-type hammers, mounted in standardized machines, in breaking standard specimens with one pendulum swing. The standard tests for these methods require specimens made with a milled notch in CHARPY and IZOD tests. |
![]() |
||||||||||||||
| Specifications : | |||||||||||||||
| Reference standard : | As per ASTM D-256 or other equivalent standards. | ||||||||||||||
| Display : | Analogue display | ||||||||||||||
| Suitable test : | IZOD, CHARPY and TENSILE Impact. | ||||||||||||||
| Range : | Maximum up to 15joules. | ||||||||||||||
| Hammer : | Pendulum type hammer and interchangeable for all test. | ||||||||||||||
|
|
|||||||||||||||
|
This method covers measurement of the rate of extrusion of molten resins through a die of a specified length and diameter under prescribed conditions of temperature, load and piston in the barrel as the timed measurement is being made. |
![]() |
||||||||||||||
| Specifications : | |||||||||||||||
| Models : | Auto cutter and Manual cutter. | ||||||||||||||
| Test temperature | 50°c up to 400°c with selectable rise of temperature range. | ||||||||||||||
| Load weights : | 2 weights : 2.16kg and 5.00kg (extra on demand) | ||||||||||||||
| Dimension of cylinder: | Bore 9.55mm | ||||||||||||||
| Length 162 mm | |||||||||||||||
| Ǿ of the piston 9.48mm | |||||||||||||||
| Dimension of orifice : | Diameter – 9.4742 mm | ||||||||||||||
| Bore – 2.095mm | |||||||||||||||
| Length – 8.00mm | |||||||||||||||
| Other orifice available on request | |||||||||||||||
| Power supply : | 220v, 50 Hz | ||||||||||||||
|
|
|||||||||||||||
|
All furnaces are constructed to customer requirements in a wide variety of diameters, lengths, sizes, and configurations, and are shipped complete with mounting brackets and accessory equipment. Heating elements are provided in various materials and configurations depending upon temperature requirements and the specific application. Furnaces have been designed for easy replacement of failed elements in the laboratory, saving you time and money. Specifications : |
![]() |
||||||||||||||
| Temperature range : | Room temperature to 1000°c. | ||||||||||||||
| Temperature resolution : | ± 1°c | ||||||||||||||
| Temperature accuracy | ± 5°c maximum. | ||||||||||||||
| Power consumption : | 2kW of tube furnace. | ||||||||||||||
| Temperature controller | Highly accurate PID based temperature controller with accuracy of 0.1% temperature in ideal condition. | ||||||||||||||
| Insulation : | Inside Ceramic construction and out side MS body with glass wool and PUF insulation to avoid heat loses. | ||||||||||||||
| Power supply : | 220v, 50 Hz. | ||||||||||||||
|
|
|||||||||||||||
|
This test machine determines the resistance to slow crack growth of polyethylene pipe expressed in terms of time to failure of the pipe with machined axial notches in hydrostatic stress rupture test. The equipment is milling kind of machine and milling cutter mounted on a horizontal shall be 60° included angel “V” cutter. |
![]() |
||||||||||||||
| Specifications : | |||||||||||||||
| Model : | Semi automatic type model. | ||||||||||||||
| Maximum Diameter : | Diameter maximum up to 250mm. | ||||||||||||||
| Cutter : | 60° equal angle cutter. | ||||||||||||||
| Depth measurement : | Depth measurement via digital dial gauge. | ||||||||||||||
| Depth length : | Depth length automatic adjustable. | ||||||||||||||
|
|
|||||||||||||||
|
This test machine covers the evaluation of specific light transmitting and wide angle light scattering properties of planar sections of materials such as essentially transparent plastic. This machine is provided for the measurement of luminous transmittance and haze. |
![]() |
||||||||||||||
| Specifications : | |||||||||||||||
| Working principal : | Machine is according to beer-Lambert law. | ||||||||||||||
| Light transmission : | Light transmission with fix constant voltage operated light source. | ||||||||||||||
| Sensor : | BPW sensor comparable to IR sensor. | ||||||||||||||
| Result constancy : | With special care to produce equipment constant result constancy. | ||||||||||||||
|
|
|||||||||||||||
|
|
|||||||||||||||
|
|
|||||||||||||||
|
Typical Testing Applications |
|||||||||||||||
| Plastics | |||||||||||||||
| Packaging | |||||||||||||||
| Metal | |||||||||||||||
| Electronics | |||||||||||||||
| Medical Device Manufacturing | |||||||||||||||
| Food | |||||||||||||||
| Automotive | |||||||||||||||
| Machinery & Manufacturing | |||||||||||||||
| Business Equipment | |||||||||||||||
| Specifications : | |||||||||||||||
| Load capacity : | Different capacity model from 10kg (100N) to 20tonnes (200kN) | ||||||||||||||
| Load accuracy : | Load accuracy as per depend on to capacity of load cell. | ||||||||||||||
| Mechanical structure : | High grade steel gives unmatched performance, accuracy and precision. High axial stiffness-reduces machine compliance while increasing speed and displacement accuracy when specimen under load. | ||||||||||||||
| Cross head driven : | Cross head driven by conventional screw and nut, guided & supported by hardened, ground finished and hard chrome plated tie rods. Gliding on linear bearings allowing the cross head motion. Ball screw driven mechanism is also available on demand. | ||||||||||||||
| Traveling length : | Maximum travel from grip to grip is 800mm at extension least count of 0.01mm. Higher length is also available on demand (optional). | ||||||||||||||
| *Speed selection : | Speed controlling by variable speed drive and speed range is from 1mm/min to 200mm/min. or 1mmmin to 500mm/min on demand. For economy application variable speed AC drives is used and in most accuracy application servo control system is also available on demand. | ||||||||||||||
| Controlling device : | Microprocessor based user’s friendly with mark identification key operating controlling system. | ||||||||||||||
| *Computer interfacing facility & software : | Machines have serial output for direct connection to computers for testing with windows™ software. Profile based software to start the test quicker, and run test fast. Gives full control of test parameters with auto set-up of the tester. Full test is analysis with statistical and graphical print-out. A report is enhancement package for long term statistics and control charts with exports in Excel™ data sheet format. | ||||||||||||||
| Grips : | Choose from a wide range of grips and fixtures for tension, compression, flexural, shear, peel, puncture and product testing. | ||||||||||||||
| Result and parameters | Max Load, Max Elongation, Yield force , Yield Elongation, Break force break elongation, GPD, Denier other customized at least two direct result value facility in corporate with the controlling unit. | ||||||||||||||
| Mode of test : | Tensile as well as compression test facility available, mode selection via software. No need to change mode every times before starting the new test. | ||||||||||||||
| Safety features : | Over load protection, reverse direction load protection, Maximum elongation protection for load cell. Both the side limit switches fitted as an additional facility. | ||||||||||||||
|
Home | About Us | Other Products | Our Customers | Contact Us | Presentation |
|||||||||||||||
|
Developed By Dips Imagination |
|||||||||||||||
| Universal Tensile tester | Tensile Tester | Hydro-static pressure tester | Melt flow Indexer | Carbon black content tester | Carbon black dispersion | Pipe V notch cutter | Plastic testing | Pipe testing, Film testing | Testing equipments | Textile Testing Machines | HDT-VSP, Izod-Charpy | Water bath, opacity | cof | dart | sealer | oilbath | Density | ESCR | End caps |
|||||||